# TestBP
|
|
|
|
## About
|
|
This repository contains source codes for client-server network application capable to communicate with distance laser sensor DLS-C 15 via RS-232 interface, which was implemented as a part of bachelor thesis.
|
|
|
|
## Author
|
|
Author: Jozef Simko
|
|
|
|
School year: 3., Bachelor study, 2021/22
|
|
|
|
Study program: Computer Networks
|
|
|
|
Organization: Technical University of Kosice (TUKE), Faculty of Electrical Engineering and Informatics (FEI)
|
|
|
|
## Building
|
|
Implemented and tested on:
|
|
| Platform | OS | compiler |
|
|
|-----------------|---------------------------|-------------------------------------------------|
|
|
| Linux | Ubuntu 20.04.1 WLS2 | gcc version 9.3.0 (Ubuntu 9.3.0-10ubuntu2) |
|
|
| Windows | Windows 10.0.19043 | gcc version 11.2.0 (MinGW-W64 x86_64-posix-seh) |
|
|
| Raspberry Pi | Linux raspberrypi 5.10.17 | gcc version 8.3.0 (Raspbian 8.3.0-6+rpi1) |
|
|
|
|
#### LINUX
|
|
* CLIENT - `gcc client.c -Wall -Werror -Wextra -o client`
|
|
* SERVER - `gcc server.c rs232.c -Wall -Werroe -Wextra -o client`
|
|
#### WINDOWS
|
|
* CLIENT - `gcc client.c -Wall -Wextra -lwsock32 -o client`
|
|
* SERVER - `gcc server.c rs232.c -lwsock32 -Wall -Werror -Wextra -o client`
|
|
|
|
## Launch
|
|
### Server
|
|
Server can be launched with 1 or 2 input parameters. The number of parameters determines what mode will be used - manual or automatic mode.
|
|
|
|
**port** - specific number to identify communication processes of server
|
|
|
|
**config_file** - configuration file with exact name of variables
|
|
|
|
#### Manual mode
|
|
- server waits for input commands from client, sends them to laser sensor and returns results back to client
|
|
- `./server <port>`
|
|
|
|
#### Automatic mode
|
|
- server loads variables from configuration file *config.txt*, starts measuring and sends results to client continuously.
|
|
- `./server <port> [config_file]`
|
|
|
|
### Client
|
|
Client has to be lauched with 2 input parameters.
|
|
|
|
**IP address** - IP address of server the client tries to connect
|
|
|
|
**port** - port number of server
|
|
|
|
- `./client <IP address> <port>`
|
|
|
|
### Demo
|
|
No input parameters.
|
|
|
|
Macros defines multiple variables used in demo program, which demonstrates connection to server in automatic mode and process of resulting data.
|
|
|
|
```c
|
|
#define IP_ADDRESS "192.168.0.101" // IP address of server
|
|
#define PORT 32500 // server port number
|
|
#define MAX_VALUE 1265 // upper limit (depends on used units)
|
|
#define MIN_VALUE 1200 // lower limit (depends on used units)
|
|
```
|
|
|
|
## References
|
|
[WinLibs GCC](https://winlibs.com)
|
|
|
|
[RS-232 library](https://www.teuniz.net/RS-232/)
|